Opened 8 years ago

Closed 8 years ago

Last modified 8 years ago

#13770 closed defect (fixed)

Grid - cannot scrolling by clicking the scroll bar up/down arrows when headers are hidden

Reported by: Evan Owned by: evan
Priority: high Milestone: 1.7
Component: DojoX Grid Version: 1.7.0b1
Keywords: Cc: grid, hidden, header, scroll
Blocked By: Blocking:

Description

It's easy to reproduce this issue by running dojox/grid/tests/test_data_grid_hideHdr.html, after clicking a certain cell, it's then impossible to scroll Grid by clicking the up/down arrows of the scroll bar.

Change History (2)

comment:1 Changed 8 years ago by Evan

Resolution: fixed
Status: newclosed

In [26388]:

Fixes #13770, by not changing focusing when clicking at the scroll bar area(or up/down arrow)

comment:2 Changed 8 years ago by Evan

In [26405]:

Refs #13770 back port the fix to 1.6 and 1.5 branches

Note: See TracTickets for help on using tickets.